Prevent and fight fire equipment » Fire alarm conventional systems » Fire alarm control panel
Fire alarm panel FAP129N-10L Code: FAP129N-10L Made in: JAPAN Producer: NOHMI BOSAI
- Save-cost and save-space.
- Conventional type.
- Alarm verification type.
- Name plate and a digital display for alarmed zones.
- Programmable output signal.
- Ni-Cd stand-by battery built in.
- Handset built in for maintenance.
- Programmable function at site.
- Automatic self-checking.
- Various test facilities for maintenance.
- Surge arrester built in for power lines.
Warranty: 12 month(s) Promotion: No
The FAP129N series fire alarm panel was developed to provide a cost- and space-saving conventional fire alarm panel together with more user-oriented functions..
The size of the panel is approximately one-half the depth, one-half the area, one-fourth the volume, and one-fifth the weight of our last 20-zone fire alarm panel..
The cabinet is made of ABS resin with non-flammability to UL-94V2.
Alarm inputs
Conventional fire detectors and manual alarm boxes are connected to alarm input circuits to give visual and audible alarm at the panel and to actuate alarm bells. The FAP129N series fire alarm panel has a line-up of 10 and 20 alarm input circuits (zones)..
Each alarm circuit has an alarm verification function.
Auxiliary inputs
Three auxiliary input signals can be connected to auxiliary input circuits to be displayed it on the panel. They may be used for non-alarm input signals..
Signal outputs
2 representative alarm signals are available.
10 voltage-free contacts are available for signal output..
A group of output signal for an Annunciator Panel..
A group of signals for a Fire Pump Starting Relay Box.
Digital display
The 2-digit digital indicator displays not only alarming zones but also trouble which happened in the fire alarm panel and in the system.
Alarm bell activation
There are 2 modes to activate alarm bells. One is to actuate all alarm bells at the same time, called general alarm. The other is to actuate a group of alarm bells depending on the location of a fire, called localized alarm.
One pair of terminals is available for the general alarm. The programmable 10 voltage-free contacts are used for the localized alarm.
Automatic self-checking
The following are automatically monitored at all time.
Detector circuits for continuity.
Connection of the battery and fuse blown-out.
Microcomputer chip and memory chips for abnormal running.
Main fuses for blown-out.
Connectors and signal transmission circuits for interruption of communication between PCB's.
Main circuit voltage for over limit and under limit.
The alarm input circuits are automatically checked once a week for normal operation..
Programming
The following are programmable for setting and canceling with a template on the panel.
Non used-alarm input circuits without putting dummy loads.
Alarm verification function to alarm-input circuits.
Interlocking auxiliary input signals with an audible alarm at the panel.
Interlocking alarm input signals with representative alarm signals.
An audible alarm at the panel during main power off.
Interlocking alarm input signals with 10 voltage-free contact outputs.
Fire protection-related device control
FAP129N series fire alarm panel has only fire alarm functions. FCS129N series fire alarm panel is available not only for fire alarm functions but also control functions for fire protection-related devices such as smoke vents, fire extinguishing system etc..
Fire alarm panel FAP232N-5L Code: FAP232N-5L Made
in: JAPAN Producer: NOHMI BOSAI
FEATURES
● Conventional type
● Alarm verification type
(Alarm verification time : 60 seconds)
● Various test functions : fire indication test, line continuity
test, auxiliary power supply test, and alarm verification
time test.
● Durable LED indications
● Back-up power supply(Ni-Cd battery, 24VDC)
● Easy maintenance
● Automatic self-checking system
DESCRIPTION
On receiving a fire signal from a fire detector or a manual
alarm box, the FAP232N-5L conventional fire alarm panel
gives visual alarms indicating the alarm point, as well as an
audible alarm, to alert the alarm panel operator. It also
produces alarms to alert the occupants of the building
premises.
The FAP232N-5L conventional fire alarm panel has
indication of the alarm points by individual zone lamps. Warranty: 12 month(s) Promotion: No
400 $
(+10%VAT) 440$
Store:
Available
View(s) 505
Fire alarm panel FAP102-R-10L Code: FAP102-R-10L Made
in: JAPAN Producer: NOHMI BOSAI
FEATURES
● Very small enclosure
● 10-zone capacity only
● Conventional type
● Switch-lock protection for operation
● Easy-to-see front panel guidance
● Alarm verification type
● Name plate display for alarmed zones
● Ni-Cd stand-by battery built in
● Telephone handset built in for maintenance
● Programmable function on front panel
● Automatic self-checking
● Various test facilities for maintenance
● Surge arrestor built in for power lines Warranty: 12 month(s) Promotion: No
Fire alarm panel RPP-EAW 05 Code: RPP-EAW05 Made
in: JAPAN Producer: HOCHIKI
RPP-EAW - Hochiki RPP-EAW
Number of Zones 5 Zones Weight Approx. 1.7Kg Dimension 230mm (W) X 330mm (H) X 63mm(D) Made JAPAN
Warranty: 12 month(s) Promotion: No
530 $
Not include VAT
Store:
Available
View(s) 363
Fire alarm panel RPQ-ABW30 Code: RPQ-ABW30 Made
in: JAPAN Producer: HOCHIKI
1. Multi purpose zone configuration
- Versatile zone configuration to suit various alarm need. (Zone 1 is preset and fixed for fire alarm
only)
2. Light weight and compact in size
- 550mm(W) X 850mm(H) X 130mm(D), Approximately 25Kg (RPQ40),
550mm(W) X 1100mm(H) X 160mm(D), Approximately 30Kg (RPQ50)
3. Easy installation
- By means of ‘Wire Insertion’ terminals
- Wide internal cabinet space of easy wiring
- 180 degree wide panel door opening
4. Time delay function
- Serves to minimize false fire alarm and improve the reliability of automatic fire alarm systems.
By verifying whether fire-related signals are being received continuously over a certain period of
time before activating the alarm and is able to dismiss many cases of potential false alarm.
- The time delay function works when 9 seconds after the first fire signal is received, this product
will reset the detector for 1 second. If a second fire signal is received within the next 40 seconds,
it will then recognize it as an outbreak of fire and activate the fire alarm.
5. New functions
- Improved lightning surge protection
- Easy configuration of local bell and interlock release control, which can be monitored from the
zone panel.
- ‘Hands-free’ intercom communication at control panel
- Voltage display for ‘Stand by Battery’ test
- Zone open circuit monitored Warranty: 12 month(s) Promotion: No
Hung Hieu Company Limited
Head Office: No. 5, Line D, Collective 354, Gr. 22, Yen Hoa Ward, Cau Giay Dist., Ha Noi City, Viet Nam
Transaction Office: No. 108, Hoa Bang St., Yen Hoa Ward, Cau Giay Dist., Ha Noi City, Viet Nam
Telephone: (84 - 4) 37821467 Fax: (84 - 4) 37821465
Email: sales@hunghieu.com.vn Website: http://hunghieu.com.vn