Fire alarm panel FAP129N-10L
Code: FAP129N-10L     Made in: JAPAN     Producer: NOHMI BOSAI
- Save-cost and save-space. - Conventional type. - Alarm verification type. - Name plate and a digital display for alarmed zones. - Programmable output signal. - Ni-Cd stand-by battery built in. - Handset built in for maintenance. - Programmable function at site. - Automatic self-checking. - Various test facilities for maintenance. - Surge arrester built in for power lines.
Warranty: 12 month(s)
Promotion: No
     
1,800 $
(+10%VAT)
1,980$
Store: Available


View(s) 5840
  Send to a friend      Document
 

DESCRIPTION.

The FAP129N series fire alarm panel was developed to provide a cost- and
space-saving conventional fire alarm panel together with more user-oriented
functions..

The size of the panel is approximately one-half the depth, one-half the area,
one-fourth the volume, and one-fifth the weight of our last 20-zone fire alarm
panel..

The cabinet is made of ABS resin with non-flammability to UL-94V2.



Alarm inputs

Conventional fire detectors and manual alarm boxes are connected to alarm input
circuits to give visual and audible alarm at the panel and to actuate alarm
bells. The FAP129N series fire alarm panel has a line-up of 10 and 20 alarm
input circuits (zones)..

Each alarm circuit has an alarm verification function.



Auxiliary inputs

Three auxiliary input signals can be connected to auxiliary input circuits to be
displayed it on the panel. They may be used for non-alarm input signals..



Signal outputs

2 representative alarm signals are available.

10 voltage-free contacts are available for signal output..

A group of output signal for an Annunciator Panel..

A group of signals for a Fire Pump Starting Relay Box.



Digital display

The 2-digit digital indicator displays not only alarming zones but also trouble
which happened in the fire alarm panel and in the system.



Alarm bell activation

There are 2 modes to activate alarm bells. One is to actuate all alarm bells at
the same time, called general alarm. The other is to actuate a group of alarm
bells depending on the location of a fire, called localized alarm.

One pair of terminals is available for the general alarm. The programmable 10
voltage-free contacts are used for the localized alarm.



Automatic self-checking

The following are automatically monitored at all time.

Detector circuits for continuity.

Connection of the battery and fuse blown-out.

Microcomputer chip and memory chips for abnormal running.

Main fuses for blown-out.

Connectors and signal transmission circuits for interruption of communication
between PCB's.

Main circuit voltage for over limit and under limit.

The alarm input circuits are automatically checked once a week for normal
operation..



Programming

The following are programmable for setting and canceling with a template on the
panel.

Non used-alarm input circuits without putting dummy loads.

Alarm verification function to alarm-input circuits.

Interlocking auxiliary input signals with an audible alarm at the panel.

Interlocking alarm input signals with representative alarm signals.

An audible alarm at the panel during main power off.

Interlocking alarm input signals with 10 voltage-free contact outputs.



Fire protection-related device control

FAP129N series fire alarm panel has only fire alarm functions. FCS129N series
fire alarm panel is available not only for fire alarm functions but also control
functions for fire protection-related devices such as smoke vents, fire
extinguishing system etc..

<< Back <<
 
OTHER PRODUCTS:
Fire alarm panel FAP232N-5L
Code: FAP232N-5L     Made in: JAPAN     Producer: NOHMI BOSAI
FEATURES ● Conventional type ● Alarm verification type (Alarm verification time : 60 seconds) ● Various test functions : fire indication test, line continuity test, auxiliary power supply test, and alarm verification time test. ● Durable LED indications ● Back-up power supply(Ni-Cd battery, 24VDC) ● Easy maintenance ● Automatic self-checking system DESCRIPTION On receiving a fire signal from a fire detector or a manual alarm box, the FAP232N-5L conventional fire alarm panel gives visual alarms indicating the alarm point, as well as an audible alarm, to alert the alarm panel operator. It also produces alarms to alert the occupants of the building premises. The FAP232N-5L conventional fire alarm panel has indication of the alarm points by individual zone lamps.
Warranty: 12 month(s)
Promotion: No
550 $
(+10%VAT)
605$
Store: Available


View(s) 6886
Fire alarm panel RPP-ECW 05
Code: RPP-ECW05     Made in: JAPAN     Producer: HOCHIKI
RPP-ECW - Hochiki RPP-EAW Number of Zones 5 Zones Weight Approx. 1.7Kg Dimension 230mm (W) X 330mm (H) X 63mm(D) Made JAPAN
Warranty: 12 month(s)
Promotion: No
550 $
Not include VAT
Store: Available


View(s) 6340
Fire alarm panel FAP102-R-10L
Code: FAP102-R-10L     Made in: JAPAN     Producer: NOHMI BOSAI
FEATURES ● Very small enclosure ● 10-zone capacity only ● Conventional type ● Switch-lock protection for operation ● Easy-to-see front panel guidance ● Alarm verification type ● Name plate display for alarmed zones ● Ni-Cd stand-by battery built in ● Telephone handset built in for maintenance ● Programmable function on front panel ● Automatic self-checking ● Various test facilities for maintenance ● Surge arrestor built in for power lines
Warranty: 12 month(s)
Promotion: No
1,500 $
(+10%VAT)
1,650$
Store: Available


View(s) 4413
Fire alarm panel RPQ-ABW30
Code: RPQ-ABW30     Made in: JAPAN     Producer: HOCHIKI
1. Multi purpose zone configuration - Versatile zone configuration to suit various alarm need. (Zone 1 is preset and fixed for fire alarm only) 2. Light weight and compact in size - 550mm(W) X 850mm(H) X 130mm(D), Approximately 25Kg (RPQ40), 550mm(W) X 1100mm(H) X 160mm(D), Approximately 30Kg (RPQ50) 3. Easy installation - By means of ‘Wire Insertion’ terminals - Wide internal cabinet space of easy wiring - 180 degree wide panel door opening 4. Time delay function - Serves to minimize false fire alarm and improve the reliability of automatic fire alarm systems. By verifying whether fire-related signals are being received continuously over a certain period of time before activating the alarm and is able to dismiss many cases of potential false alarm. - The time delay function works when 9 seconds after the first fire signal is received, this product will reset the detector for 1 second. If a second fire signal is received within the next 40 seconds, it will then recognize it as an outbreak of fire and activate the fire alarm. 5. New functions - Improved lightning surge protection - Easy configuration of local bell and interlock release control, which can be monitored from the zone panel. - ‘Hands-free’ intercom communication at control panel - Voltage display for ‘Stand by Battery’ test - Zone open circuit monitored
Warranty: 12 month(s)
Promotion: No
3,200 $
(+10%VAT)
3,520$
Store: Available


View(s) 3608
Fire alarm panel RPP-ABW20
Code: RPP-ABW 20     Made in: JAPAN     Producer: HOCHIKI
Features 1. Multi purpose zone configuration - Versatile zone configuration to suit various alarm need. (Zone 1 is preset and fixed for fire alarm only) 2. Light weight and compact in size - 450mm(W) X 650mm(H) X 100mm(D), Approximately 13Kg 3. Easy installation - By means of ‘Wire Insertion’ terminals - Wide internal cabinet space of easy wiring - 180 degree wide panel door opening 4. Improved local bell control with programmable ‘silence’ timer - If the local bell is put on ‘silence’ mode after an initial alarm signal, any subsequent zone activation immediately re-triggers the local alarm. And should the system be left at ‘silence’ mode without subsequent zone activation, the local alarm will automatically trigger again after a custom preset time period from the first alarm activation. - The custom preset timer can be programmed to reactivate the local alarm after 2,4,6 or 8 minutes from the first alarm activation. 5. New functions - Improved lightning surge protection - Easy configuration of local bell and interlook release control, which can be monitored from the zone panel. - Functional test equipped with 2 reset modes for heat and smoke detectors. - ‘Hands-free’ intercom communication at control panel - Voltage display for ‘Stand by Battery’ test - Sound alert during ‘Time Delay’ operation - Optional pre-alarm alert for ‘Time Delay’ operation - Zone open circuit monitored
Warranty: 12 month(s)
Promotion: No
2,800 $
Not include VAT
Store: Available


View(s) 3105
 
LIVE SUPPORT
HOTLINE: 0989223439
SALE SUPPORT  
Ms. Hà 
0903468844 
hvt3008 

TECHNICAL SUPPORT  
Camera, PCCC, LED 
0989223439 
hunghieus 
My status leoboss2004 
hunghieucom@vnn.vn 

MEMBER
Username

Password

Remember


Forgot password?
New member? Register!
(Register for better price)
CART
  Products (0)
View cart
Send order
Empty cart
 
LINKS
Nohmi Bosai Ltd
HOCHIKI
Apollo Fire